3.7 CMD_STATUS2

The status2 command returns the status of the corresponding port, including an additional hardware error byte from the MAX14819 channel status register. It is an extended version of CMD_STATUS (0x06).

Command:

Octet # Usage
0 Command ID = 0x08
1 Port index 0x00 or 0x01

Return Success:

Octet # Usage Comment
0 Command ID = 0x08
1 Port index 0x00 or 0x01
2 Process data IN valid 0x00 = Not valid 0x01 = Valid
3 Process data OUT valid
4 Transmission rate 0x00 = Detection Failure 0x01 = COM1 (4.8 kbps) 0x02 = COM2 (38.4 kbps) 0x03 = COM3 (230.4 kbps)
5 Process data IN length
6 Cycle time
7 Process data OUT length
8..9 Vendor ID 16-bit value
10..13 Device ID 32-bit value
14 Power 0x00 = Power OFF 0x01 = Power ON