| Control | Description |
| Mode: Auto | The scope re-arms automatically after each capture, continuously refreshing the waveform. |
| Mode: Single | Captures one waveform after the next trigger event, then holds. |
| Mode: Manual | Does not arm automatically; use the “Force” button to capture regardless of trigger condition. |
| Force button | Immediately captures the current signal. Available in Manual mode only. |
| Trigger Level | Adjusts the threshold at which the scope triggers. Changes take effect after immediately |
| Save | Explicitly saves the current trigger level back to the trigger or timer configuration on the settings page. |
| X (Close button) | Closes the scope and stops acquisition. |