<?xml version="1.0" encoding="UTF-8"?>
<!-- generator="FeedCreator 1.8" -->
<?xml-stylesheet href="https://doc.pinetek-networks.com/lib/exe/css.php?s=feed" type="text/css"?>
<rdf:RDF
    xmlns="http://purl.org/rss/1.0/"
    xmlns:rdf="http://www.w3.org/1999/02/22-rdf-syntax-ns#"
    xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
    xmlns:dc="http://purl.org/dc/elements/1.1/">
    <channel rdf:about="https://doc.pinetek-networks.com/feed.php">
        <title>Pinetek Networks - Knowledge Base</title>
        <description></description>
        <link>https://doc.pinetek-networks.com/</link>
        <image rdf:resource="https://doc.pinetek-networks.com/lib/exe/fetch.php?media=wiki:logo.png" />
       <dc:date>2026-11-02T15:15:06+00:00</dc:date>
        <items>
            <rdf:Seq>
                <rdf:li rdf:resource="https://doc.pinetek-networks.com/doku.php?id=iol-hat:sw:3_binary-protocol:3.7_cmd-status2&amp;rev=1792489522&amp;do=diff"/>
                <rdf:li rdf:resource="https://doc.pinetek-networks.com/doku.php?id=iol-hat:sw:3_binary-protocol:3.4_cmd-read&amp;rev=1792349883&amp;do=diff"/>
                <rdf:li rdf:resource="https://doc.pinetek-networks.com/doku.php?id=iol-hat:sw:3_binary-protocol:3.8_cmd-status3&amp;rev=1791770588&amp;do=diff"/>
                <rdf:li rdf:resource="https://doc.pinetek-networks.com/doku.php?id=iol-hat:sw:3_binary-protocol:3.5_cmd-write&amp;rev=1791432020&amp;do=diff"/>
                <rdf:li rdf:resource="https://doc.pinetek-networks.com/doku.php?id=iol-hat:sw:3_binary-protocol:3.6_cmd-status&amp;rev=1790633163&amp;do=diff"/>
                <rdf:li rdf:resource="https://doc.pinetek-networks.com/doku.php?id=iol-core:hw:06_compliance&amp;rev=1789501811&amp;do=diff"/>
                <rdf:li rdf:resource="https://doc.pinetek-networks.com/doku.php?id=iol-hat:hw:3_specifications-support-supplier:3.3_supplier&amp;rev=1789501796&amp;do=diff"/>
                <rdf:li rdf:resource="https://doc.pinetek-networks.com/doku.php?id=iol-hat:hw:3_specifications-support-supplier:3.1_technical-specifications&amp;rev=1789501741&amp;do=diff"/>
                <rdf:li rdf:resource="https://doc.pinetek-networks.com/doku.php?id=iol-core:hw:04_interface&amp;rev=1789501706&amp;do=diff"/>
                <rdf:li rdf:resource="https://doc.pinetek-networks.com/doku.php?id=iol-hat:hw:2_connections:2.2_40-pin-gpio-jumpers&amp;rev=1789501662&amp;do=diff"/>
                <rdf:li rdf:resource="https://doc.pinetek-networks.com/doku.php?id=iol-core:hw:03_outlines_connector_positions&amp;rev=1789501640&amp;do=diff"/>
                <rdf:li rdf:resource="https://doc.pinetek-networks.com/doku.php?id=iol-core:hw:05_environmental_requirements&amp;rev=1789501515&amp;do=diff"/>
                <rdf:li rdf:resource="https://doc.pinetek-networks.com/doku.php?id=iol-core:hw:02_system_architecture&amp;rev=1789501455&amp;do=diff"/>
                <rdf:li rdf:resource="https://doc.pinetek-networks.com/doku.php?id=iol-core:hw:01_introduction&amp;rev=1789501390&amp;do=diff"/>
                <rdf:li rdf:resource="https://doc.pinetek-networks.com/doku.php?id=iol-hat:hw:1_basics:1.1_introduction&amp;rev=1789501322&amp;do=diff"/>
                <rdf:li rdf:resource="https://doc.pinetek-networks.com/doku.php?id=wiki:ebook:iol_core_hw&amp;rev=1789501218&amp;do=diff"/>
            </rdf:Seq>
        </items>
    </channel>
    <image rdf:about="https://doc.pinetek-networks.com/lib/exe/fetch.php?media=wiki:logo.png">
        <title>Pinetek Networks - Knowledge Base</title>
        <link>https://doc.pinetek-networks.com/</link>
        <url>https://doc.pinetek-networks.com/lib/exe/fetch.php?media=wiki:logo.png</url>
    </image>
    <item rdf:about="https://doc.pinetek-networks.com/doku.php?id=iol-hat:sw:3_binary-protocol:3.7_cmd-status2&amp;rev=1792489522&amp;do=diff">
        <dc:format>text/html</dc:format>
        <dc:date>2026-10-20T09:45:22+00:00</dc:date>
        <dc:creator>Anonymous (anonymous@undisclosed.example.com)</dc:creator>
        <title>3.7 CMD_STATUS2 - removed - external edit (Unknown date)</title>
        <link>https://doc.pinetek-networks.com/doku.php?id=iol-hat:sw:3_binary-protocol:3.7_cmd-status2&amp;rev=1792489522&amp;do=diff</link>
        <description>3.7 CMD_STATUS2

The status2 command returns the status of the corresponding port, including an additional hardware error byte from the MAX14819 channel status register. It is an extended version of CMD_STATUS (0x06).

Command:
 Octet #  Usage  0  Command ID = 0x08</description>
    </item>
    <item rdf:about="https://doc.pinetek-networks.com/doku.php?id=iol-hat:sw:3_binary-protocol:3.4_cmd-read&amp;rev=1792349883&amp;do=diff">
        <dc:format>text/html</dc:format>
        <dc:date>2026-10-18T18:58:03+00:00</dc:date>
        <dc:creator>Anonymous (anonymous@undisclosed.example.com)</dc:creator>
        <title>3.4 CMD_READ - removed - external edit (Unknown date)</title>
        <link>https://doc.pinetek-networks.com/doku.php?id=iol-hat:sw:3_binary-protocol:3.4_cmd-read&amp;rev=1792349883&amp;do=diff</link>
        <description>3.4 CMD_READ

This command reads a parameter with the index and subindex as given on the corresponding port.

Command:
 Octet #  Usage  0  Command ID = 0x04  1  Port index 0x00 or 0x01  2..3  Index, 16-bit value  4  Subindex  5  Length 
The **Length **</description>
    </item>
    <item rdf:about="https://doc.pinetek-networks.com/doku.php?id=iol-hat:sw:3_binary-protocol:3.8_cmd-status3&amp;rev=1791770588&amp;do=diff">
        <dc:format>text/html</dc:format>
        <dc:date>2026-10-12T02:03:08+00:00</dc:date>
        <dc:creator>Anonymous (anonymous@undisclosed.example.com)</dc:creator>
        <title>3.8 CMD_STATUS3 - removed - external edit (Unknown date)</title>
        <link>https://doc.pinetek-networks.com/doku.php?id=iol-hat:sw:3_binary-protocol:3.8_cmd-status3&amp;rev=1791770588&amp;do=diff</link>
        <description>3.8 CMD_STATUS3

The status3 command returns the chip-level status register of the MAX14819 transceiver. Unlike CMD_STATUS and CMD_STATUS2, this command is not port-specific and requires only a single command byte (no port index). The returned value is the content of the MAX14819 REG_Status register (0x1E) OR&#039;d with any error bits that were latched since the last call to CMD_STATUS3. Reading this command clears the latch.</description>
    </item>
    <item rdf:about="https://doc.pinetek-networks.com/doku.php?id=iol-hat:sw:3_binary-protocol:3.5_cmd-write&amp;rev=1791432020&amp;do=diff">
        <dc:format>text/html</dc:format>
        <dc:date>2026-10-08T04:00:20+00:00</dc:date>
        <dc:creator>Anonymous (anonymous@undisclosed.example.com)</dc:creator>
        <title>3.5 CMD_WRITE - removed - external edit (Unknown date)</title>
        <link>https://doc.pinetek-networks.com/doku.php?id=iol-hat:sw:3_binary-protocol:3.5_cmd-write&amp;rev=1791432020&amp;do=diff</link>
        <description>3.5 CMD_WRITE

This command writes a parameter with the index and subindex as given on the addressed port.

Command:
 Octet #  Usage  0  Command ID = 0x05  1  Port index 0x00 or 0x01  2..3  Index, 16-bit value  4  Subindex  5  Length  6..  Write Data</description>
    </item>
    <item rdf:about="https://doc.pinetek-networks.com/doku.php?id=iol-hat:sw:3_binary-protocol:3.6_cmd-status&amp;rev=1790633163&amp;do=diff">
        <dc:format>text/html</dc:format>
        <dc:date>2026-09-28T22:06:03+00:00</dc:date>
        <dc:creator>Anonymous (anonymous@undisclosed.example.com)</dc:creator>
        <title>3.6 CMD_STATUS - removed - external edit (Unknown date)</title>
        <link>https://doc.pinetek-networks.com/doku.php?id=iol-hat:sw:3_binary-protocol:3.6_cmd-status&amp;rev=1790633163&amp;do=diff</link>
        <description>3.6 CMD_STATUS

The status command returns the status of the corresponding port.

Command:
 Octet #  Usage  0  Command ID = 0x06  1  Port index 0x00 or 0x01 
Return Success:
 Octet #  Usage  Comment  0  Command ID = 0x06    1  Port index 0x00 or 0x01</description>
    </item>
    <item rdf:about="https://doc.pinetek-networks.com/doku.php?id=iol-core:hw:06_compliance&amp;rev=1789501811&amp;do=diff">
        <dc:format>text/html</dc:format>
        <dc:date>2026-09-15T19:50:11+00:00</dc:date>
        <dc:creator>anla (anla@undisclosed.example.com)</dc:creator>
        <title>6. Compliance Requirements</title>
        <link>https://doc.pinetek-networks.com/doku.php?id=iol-core:hw:06_compliance&amp;rev=1789501811&amp;do=diff</link>
        <description>6. Compliance Requirements

Compliance assessment for the regions EU, US, and Canada (not legally binding). The IOL Core4 is an extension board for integration into control, testing, or measurement hardware; it is not a standalone device and is only sold as a component for integration into other products.</description>
    </item>
    <item rdf:about="https://doc.pinetek-networks.com/doku.php?id=iol-hat:hw:3_specifications-support-supplier:3.3_supplier&amp;rev=1789501796&amp;do=diff">
        <dc:format>text/html</dc:format>
        <dc:date>2026-09-15T19:49:56+00:00</dc:date>
        <dc:creator>anla (anla@undisclosed.example.com)</dc:creator>
        <title>3.3 Supplier information</title>
        <link>https://doc.pinetek-networks.com/doku.php?id=iol-hat:hw:3_specifications-support-supplier:3.3_supplier&amp;rev=1789501796&amp;do=diff</link>
        <description>3.3 Supplier information

Pinetek Networks GmbH
Bachstelzenweg 8
DE-88677 Markdorf

www.pinetek-networks.com
info@pinetek-networks.com

Disposal

The IOL HAT is marked with the crossed out waste bin symbol with shows the compliance with the WEEE. Pinetek Networks will take back devices that are used in a B2B environment. For devices, that are used in B2C environments, the local disposal through local services, or they can be returned to Pinetek Networks.</description>
    </item>
    <item rdf:about="https://doc.pinetek-networks.com/doku.php?id=iol-hat:hw:3_specifications-support-supplier:3.1_technical-specifications&amp;rev=1789501741&amp;do=diff">
        <dc:format>text/html</dc:format>
        <dc:date>2026-09-15T19:49:01+00:00</dc:date>
        <dc:creator>anla (anla@undisclosed.example.com)</dc:creator>
        <title>3.1 Technical Specifications</title>
        <link>https://doc.pinetek-networks.com/doku.php?id=iol-hat:hw:3_specifications-support-supplier:3.1_technical-specifications&amp;rev=1789501741&amp;do=diff</link>
        <description>3.1 Technical Specifications

Transceiver

	*  Dual IO-Link Master Transceiver Analog Devices MAX14816 with Integrated Framers and L+ Supply Controllers
	*  SPI-Mode only (RX/TX not used)

Mechanical

Dimensions

	*  65,5 × 66 mm
	*  Height: 18 mm with stack-through</description>
    </item>
    <item rdf:about="https://doc.pinetek-networks.com/doku.php?id=iol-core:hw:04_interface&amp;rev=1789501706&amp;do=diff">
        <dc:format>text/html</dc:format>
        <dc:date>2026-09-15T19:48:26+00:00</dc:date>
        <dc:creator>anla (anla@undisclosed.example.com)</dc:creator>
        <title>4. Interface</title>
        <link>https://doc.pinetek-networks.com/doku.php?id=iol-core:hw:04_interface&amp;rev=1789501706&amp;do=diff</link>
        <description>4. Interface

4.1 General Considerations

	*  The host connector and IOL connectors are 2,54mm pitch pin header with a pin length of 6mm.
	*  The clearance under the board shall be min. H=3,5mm.



4.2 Power Supply

	*  The 24V power supply voltage shall be 24V +/- 20%.</description>
    </item>
    <item rdf:about="https://doc.pinetek-networks.com/doku.php?id=iol-hat:hw:2_connections:2.2_40-pin-gpio-jumpers&amp;rev=1789501662&amp;do=diff">
        <dc:format>text/html</dc:format>
        <dc:date>2026-09-15T19:47:42+00:00</dc:date>
        <dc:creator>anla (anla@undisclosed.example.com)</dc:creator>
        <title>2.2 40-pin GPIO to Raspberry Pi and jumper settings (PT-1201 only)</title>
        <link>https://doc.pinetek-networks.com/doku.php?id=iol-hat:hw:2_connections:2.2_40-pin-gpio-jumpers&amp;rev=1789501662&amp;do=diff</link>
        <description>2.2 40-pin GPIO to Raspberry Pi and jumper settings (PT-1201 only)

This connector provides the connection to the Raspberry Pi over the standard 40-pin GPIO connector:



This connector is implemented as stack-through, i.e. up to two IOL HATs can be connected on top of each other. If the pins are not occupied by the connected IOL HAT, additional expansion boards can be connected via the stack-through connector.</description>
    </item>
    <item rdf:about="https://doc.pinetek-networks.com/doku.php?id=iol-core:hw:03_outlines_connector_positions&amp;rev=1789501640&amp;do=diff">
        <dc:format>text/html</dc:format>
        <dc:date>2026-09-15T19:47:20+00:00</dc:date>
        <dc:creator>anla (anla@undisclosed.example.com)</dc:creator>
        <title>3. Outlines and Connector Positions</title>
        <link>https://doc.pinetek-networks.com/doku.php?id=iol-core:hw:03_outlines_connector_positions&amp;rev=1789501640&amp;do=diff</link>
        <description>3. Outlines and Connector Positions

3.1 Top and Bottom Definition



Ensure the correct orientation of the IOL Core4 module. Misalignment or rotation can cause damage on the host system and the IOL Core4. Do not plug or unplug while powered.

3.2 Outlines and Positions (TOP View)</description>
    </item>
    <item rdf:about="https://doc.pinetek-networks.com/doku.php?id=iol-core:hw:05_environmental_requirements&amp;rev=1789501515&amp;do=diff">
        <dc:format>text/html</dc:format>
        <dc:date>2026-09-15T19:45:15+00:00</dc:date>
        <dc:creator>anla (anla@undisclosed.example.com)</dc:creator>
        <title>5. Environmental Requirements</title>
        <link>https://doc.pinetek-networks.com/doku.php?id=iol-core:hw:05_environmental_requirements&amp;rev=1789501515&amp;do=diff</link>
        <description>5. Environmental Requirements

Operating temperature range: -25°C to +60°C.

The IOL Core4 was tested with a host board with an environmental temperature of 50°C. The final temperature rating needs to be done with the host hardware in the integrated setup.</description>
    </item>
    <item rdf:about="https://doc.pinetek-networks.com/doku.php?id=iol-core:hw:02_system_architecture&amp;rev=1789501455&amp;do=diff">
        <dc:format>text/html</dc:format>
        <dc:date>2026-09-15T19:44:15+00:00</dc:date>
        <dc:creator>anla (anla@undisclosed.example.com)</dc:creator>
        <title>2. System Architecture</title>
        <link>https://doc.pinetek-networks.com/doku.php?id=iol-core:hw:02_system_architecture&amp;rev=1789501455&amp;do=diff</link>
        <description>2. System Architecture

2.1 IOL Core4



2.2 IOL Core4 Pro</description>
    </item>
    <item rdf:about="https://doc.pinetek-networks.com/doku.php?id=iol-core:hw:01_introduction&amp;rev=1789501390&amp;do=diff">
        <dc:format>text/html</dc:format>
        <dc:date>2026-09-15T19:43:10+00:00</dc:date>
        <dc:creator>anla (anla@undisclosed.example.com)</dc:creator>
        <title>1. Introduction</title>
        <link>https://doc.pinetek-networks.com/doku.php?id=iol-core:hw:01_introduction&amp;rev=1789501390&amp;do=diff</link>
        <description>1. Introduction

1.1 Purpose

The IOL Core4 is a compact IO-Link®  master module designed for integration into embedded host systems. It provides four IO-Link ports compliant with IEC 61131-9 (SDCI), enabling direct connectivity to industrial sensors and actuators in IIoT and automation applications.</description>
    </item>
    <item rdf:about="https://doc.pinetek-networks.com/doku.php?id=iol-hat:hw:1_basics:1.1_introduction&amp;rev=1789501322&amp;do=diff">
        <dc:format>text/html</dc:format>
        <dc:date>2026-09-15T19:42:02+00:00</dc:date>
        <dc:creator>anla (anla@undisclosed.example.com)</dc:creator>
        <title>1.1 Introduction</title>
        <link>https://doc.pinetek-networks.com/doku.php?id=iol-hat:hw:1_basics:1.1_introduction&amp;rev=1789501322&amp;do=diff</link>
        <description>1.1 Introduction

Thanks for purchasing an IOL HAT module. Please read this information carefully to ensure safe and hassle-free operation of the device. The application of this product is intended for users, that have experience with electronic devices and programming.</description>
    </item>
    <item rdf:about="https://doc.pinetek-networks.com/doku.php?id=wiki:ebook:iol_core_hw&amp;rev=1789501218&amp;do=diff">
        <dc:format>text/html</dc:format>
        <dc:date>2026-09-15T19:40:18+00:00</dc:date>
        <dc:creator>anla (anla@undisclosed.example.com)</dc:creator>
        <title>iol_core_hw - Selection stored</title>
        <link>https://doc.pinetek-networks.com/doku.php?id=wiki:ebook:iol_core_hw&amp;rev=1789501218&amp;do=diff</link>
        <description>iol_core_hw

	*  1. Introduction
	*  2. System Architecture
	*  3. Outlines and Connector Positions
	*  4. Interface
	*  5. Environmental Requirements
	*  6. Compliance Requirements</description>
    </item>
</rdf:RDF>
